Application of Low-voltage Reactive Power Compensation in Saving Energy and Reducing Consumption

Xu Shuang

Ankerui Electric Co., Ltd., Shanghai Jiading 201801

I. Introduction

The power supply system of a metallurgical workshop in Jiangyin is 10kV, one of which is a 10/0.4kV transformer with a capacity of 800kV•A. The load rate of the transformer is about 65%. The main load is the AC motor (inductive load). The power factor is around 0.5. In order to increase the power factor and reduce unnecessary electricity expenses, Ankerui's low-voltage reactive power compensator was selected. Through the use of the low-voltage reactive power compensator, the energy-saving effect is very good and the electricity expenses are reduced.
Second, the choice of ARC power factor controller

Ancorui's ARC power factor controller strictly complies with the requirements specified in professional standards such as DL/T597 "Low-Voltage Reactive Power Compensation Controller Ordering Specifications" and JB/T9663 "Low-Voltage Reactive Power Automatic Compensation Controller" and other professional standards. According to the demand and load characteristics of the low voltage distribution network. In general, the controller can be selected from the following aspects:

Table 1 Product Application

model

Load requirements

Compensation method

Switch

Capacitor

Compensation plan

ARC-6/J

ARC-8/J

ARC-10/J

ARC-12/J

Three-phase balanced load; and the reactive power is relatively stable, and users who do not need frequent switching of capacitance compensation are required.

Single-load (high-power motor) on-site compensation and low-voltage switchgear centralized compensation

Contactor

Self-healing power capacitor

Three-phase total compensation

ARC-6/R

ARC-8/R

ARC-10/R

ARC-12/R

Three-phase balanced load, or variable load, impact load.

Single-load (high-power motor) on-site compensation and low-voltage switchgear centralized compensation

Capacitive non-contact switching switch

Self-healing power capacitor

Three-phase total compensation

ARC-12F-J

ARC-16F-J

Three-phase balanced load; and the reactive power is relatively stable, and users who do not need frequent switching of capacitance compensation are required.

Single-load (high-power motor) on-site compensation and low-voltage switchgear centralized compensation

Contactor

Self-healing capacitor

Three-phase total compensation, sub-supplement

ARC-12F-R

ARC-16F-R

Three-phase balanced load, or three-phase unbalanced load, variable load, impact load.

Single-load (high-power motor) on-site compensation and low-voltage switchgear centralized compensation

Capacitive non-contact switching switch

Self-healing power capacitor

Three-phase total compensation, sub-supplement

Table 2 Product Selection

Product number

Function selection table

Static output

Dynamic output

Overvoltage

Undervoltage

Overcurrent

Under current

Temperature protection

Phase protection

Harmonic protection

communication

Encoding

ARC-6/J

√

√

√

√

√

√

ARC-6/R

√

ARC-8/J

√

√

√

√

√

√

ARC-8/R

√

ARC-10/J

√

√

√

√

√

√

ARC-10R

√

ARC-12/J

√

√

√

√

√

√

ARC-12/R

√

ARC-12F-J

√

√

√

√

√

can

selected

√

√

Optional

√

ARC-12F-R

√

ARC-16F-J

√

√

√

√

√

can

selected

√

√

Optional

√

ARC-16F-R

√

Third, the choice of reactive power compensation capacity

When the reactive power compensation capacity is mainly for the purpose of increasing the power factor, the choice of compensation capacity is divided into two major categories, namely, the selection of single-load local compensation capacity (mainly motor) and the selection of multi-load compensation capacity (referring to centralized and local grouping). make up) .

3.1 Selection of Local Load Compensation Capacity for Single Load

(1) US data recommendation: Q c = ( 1/3) P e (1/3 of rated capacity)

(2) Empirical coefficient method: Since the number of motor poles is different, the capacitor with a capacity closer to the actual need is determined by determining the empirical coefficient of the number of poles. When this method is generally used at 70% load, the post-compensation power factor may be 0.95 to 0.97. between.

Table 3 Empirical coefficient method

3.2 Selection of Multiple Load Compensation Capacity

The selection of multi-load compensation capacity is determined based on the power factor before and after compensation. Reactive power compensation capacity Qc is as follows:

Fourth, the effectiveness of reactive power compensation

Ankerui's controllers installed reactive power compensation devices on the side of the low-voltage line distribution cabinet of Jiangyin Metallurgical Co., Ltd. From the results of post-installation tests, the average current is reduced by 40 (A). The motor power factor is from The increase of 0.5 to 0.95 has reduced the consumption of the company's internal low-voltage power grid. The monthly electricity bill has been reduced from 12,000 yuan/month to 8,000 yuan/month, achieving the purpose of saving electricity. Due to the reduced input of reactive power in the grid, the metallurgical company benefits.

references:

[1] Ankerui Electric Co., Ltd. Product Selection Guide 2013.1.

About the Author:

Xu Shuang, female, undergraduate, Ankerui Electric Co., Ltd., the main research direction is reactive power compensation and active filter device design; Email: Mobile QQ

PVC Self-Repair High Speed Zipper Door

Zipper quick door

The curtain of the high-speed zipper door is made of 1.2MM PVC coating cloth which can be embedded into the window. The unique design of this zipper door makes it possible to provide efficient goods entrance and exit under the premise of minimizing heat loss, so as to maintain the original temperature conditions in the room. The high-speed zipper door can provide different opening and closing speeds. According to the different needs of customers to provide the best speed of adaptation. The high speed zipper door curtain section ensures the safety of equipment and personnel without any solid parts. The high speed zipper door has a self-repair function, which means that even if the curtain is derailed in the middle (e.g., hit by a forklift), The self-healing system will automatically guide the curtain rerail in the next loop.) We can do this in the event that the front or back of the door hits the curtain and derails.

The new zipper is professional for derailed repair zipper door, zipper head material nylon 66, with built-in steel wire rope and screws fixed curtain, under the impact of gravity can let the curtain out of the rapid and correct return to the track, and track teeth without damage, durable, improve the original zipper teeth easy to wear defects.


PVC auto-repair fast door,automatic industrial sectional door, PVC Self-recovery high speed door,rapid PVC high speed door,self-repairing high speed doors

SHENZHEN HONGFA AUTOMATIC DOOR CO., LTD , https://www.hongfahss.com