90kw Industrial Air Cooled Module Water Chiller

  • Model NO.: HWAC
  • Cooling Method: Air-cooled
  • Selected Voltage: 220V, 380V, 160V, 440V etc.
  • Noise Level: Ultra Low
  • Application Machine: Combination machine
  • Condition: New
  • Cooling Capacity: 39-256kw
  • Cooling Power Input: 14-95kw
  • Compressor Type: Hermetic Twin Scroll
  • Max.Ambient Working Temp: 45 Degree C
  • Weight: 580-1870kgs
  • Transport Package: Plastc+Foam+Woden Case
  • Origin: Guangdong Foshan
  • Type: Air-Cooled
  • Unit Structure: Integral
  • Compressor Number: It Depend on The Cooling Capacity
  • Application Fields: Air Conditioning
  • Certification: ISO, CE
  • Name: 90kw Industrial Air Cooled Module Water Chiller
  • Heating Capacity: 41-272kw
  • Heating Power Input: 14.8-98kw
  • Refrigerant: R22/R407cr410A etc
  • Air Side Exchanger: Aluminum Fin with Female Copper Tube
  • Trademark: Headpower
  • Specification: 1unit/case
  • HS Code: 8418692090
1)The Feature of 90kw Industrial Air Cooled Module Water Chiller
a.High reliability
The heat transmission media is water, and sufficient water pump lift will ensure the remote provision of coled and heat.In addtion,the refrigerant pipes are located outdoors,reduce the possibity of refrigerant leakage.The two-system unit enjoys two separate refrigerating systems, which further enhancethe reliability of the unit.
b.High configuration,Lower costs
The single or double system units are all equipeed with expansion thanks ,enhancing the reliaility of the water system,reducing user'sproject investment and maintenance costs.
c.Wide scope of working
The unit is able to perform refrigerantion in 50ºC environmental temperature and produce heat in-10ºC temperature
d.Intelligent control
The main control system is advanced computer control system,is able to conduct overall control over the unit.Through the multi-point control function,main body start and shutdown can be under control in any room, namely the main body will start only one terminal device gives the order of tart or will shut down when al terminal device give the order of shutdown.The chiefcontrol point can be set at any room for the preferable control of the unit.
e.Cost-effective running
The two-system unit is able to run one or two system according to the actual air conditioner load;the built-in expansion tank increases the water volume of the system,reduces the times of compressor start or stop,guarantees the balance of energy supply and need,and ensures the high effciency and security of the unit running.
f .Low-noise running:
Superior ultra-low noise axial-flow fan, multi-level stainless steel centrifugal pump and other advanced noise reduction techniques are adopted,greatly reducing the running noise of air conditioner and offering you and environment free from noise pollution

2)Product model:
Parameters                             Type HWAC03/D HWAC05/D HWAC05 HWAC06 HWAC08 HWAC10 HWAC12 HWAC15
HWAC03H/D HWAC05H/D HWAC05H HWAC06H HWAC08H HWAC10H HWAC12H HWAC15H
Cooling Capacity KW 7.1 13 13.3 16 21.8 26 32 39
Heating Capacity KW 7.2 13.5 13.8 16.5 23 27.5 34 41.5
Power supply   220V/1PH-50HZ 380V/3PH-50HZ(Optional: 440V/3PH/60Hz)
Cooling Power Input KW 2.9 4.2 4.28 5.4 7 9.8 12.8 14.5
Heating Power Input KW 3 4.25 4.3 5.5 7.1 10 13.6 15
Switch of Cooling/Heating   Four way valve
Protection Devices high and low pressure protection,anti-frozen protection,over load protection,phase order protection,over-heat protection of compressor
Operation Equipments microcomputer control automatically,failure warning 
Compressor Type hermetic rotary compressor hermetic scroll compressor
Power KW 2.23 2.23×2 3.75 4.5 3.75+2.23 3.75×2 4.5×2 3.75×3
Air Side Heat Exchanger Type copper tube with aluminum fin
Fan Type ultra-low noise axial type 
Air Blowing Direction vertical side blowing vertical top blowing
Air Flow m3/h 4000 6200 6200 6800 8000 11000 12500 15000
Fan Power KW 0.25 0.25 0.25 0.25 0.25×2 0.25×2 0.25×2 0.55×2
Water Side  Heat Exchanger Type stainless steel plate/high efficiency shell and tube type
Water Resistance kpa 30 35 35 39 42 45 45 46
Connecting Pipe inch 1"/DN25 1"/DN25 1"/DN25 1"/DN25 1"/DN25        /DN32         /DN32         /DN40
Water Pump Water Flow m3/h 1.6 2.8 2.8 3.2 4 4.8 6 7.5
External Pressure Head m 22 22 22 22 22 20 20 20
Rated Power KW 0.55 0.55 0.55 0.55 0.75 0.75 1.1 1.5
Refrigerant R22/R407C
Volume Control   Thermostatic expansion valve
Volume of Expansion Tank Inside  L 5 8
Operation Noise Level dB(A) 56 58 58 58 60 61 61 63
Net Weight kg 136 130 156 200 260 300 360 580
Unit  Dimensions Length mm 950 1200 1200 1200 1600 1800 1800 2000
Width mm 600 650 650 650 850 900 900 1000
Height mm 1550 1550 1550 1550 1500 1500 1600 1800
  Note:                  
  1. "D" means single phase power supply,"H" means heat pump type;                  
  2. Nominal cooling condition: outside air temperature DB35ºC/WB24ºC, chilled water temperature 12/7ºC;                  
  3. Nominal heating condition: ambient air temperature DB7ºC/WB6ºC, inlet/outlet water temperature 40/45ºC;                  
  4. The units contain water pump and expansion tank;                  
  5. Owing to technological advances, the above specifications are subject to change without notice.                  
  6. Optional device: heat recovery system.                   
3) Dispaly:
90kw Industrial Air Cooled Module Water Chiller
4)Packing and shipping
90kw Industrial Air Cooled Module Water Chiller

5)Our company file

90kw Industrial Air Cooled Module Water Chiller6)Company Culture:

Serve the society with technology, serve the customer with    heart, become a  first level air conditioning company in China.
Innovation, loyalty, responsibility, value.
Provide customer with high quality product and considerable service.

7)Our services:

1) Changing on material, color, shape, construction:Acceptable.
2) General inspection on fixing before packing
4) We can offer you premium quality , competitive price, prompt delivery and low minimum orders.
5) OEM,ODM service.

8)Project and client:

No

Project Name ( China)

Industry

Area

1

Zhongshan people hospital

Hospital

Zhongshan

2

Hankou Railway Station, Union Hospital, Wuhan Branch

Hospital

Wuhan

3

Wuhan City, Wuchang Railway Hospital

Hospital

Wuhan

4

Three townships Zhongshan People's Hospital

Hospital

Zhongshan

5

Zhujiang hospital of Guangzhou

Hospital

Guangzhou

6

Zhongshan Garden Hotel

Hotel   industry

Zhongshan

7

Western Sunshine Hotel, Zhongshan

Hotel   industry

Zhongshan

8

Shunde Golden Hotel

Hotel   industry

Foshan

9

East China Hotel in Guangzhou

Hotel   industry

Guangzhou

10

Nanyou Zhuhai hotel

Hotel   industry

Zhuhai

No

Company Name ( Overseas)

Product

Country

1

SB Global Energy

Air cooled ducted split

Holland

2

Bentos pharmaceutical products Ltd.

Clean air conditioners

Nigeria

3

SOGAMEF

Air cooled chiller

Gabon

4

SeaService shipping

Marine air conditioner

Russia

5

EURO STANDARD LIMITED

Fresh Air Handling Unit

New Zealand

6

Henrich trading center

Air cooled/water cooled air conditioner

Philippines

7

Marine Engineering Systems Pte.Ltd

AHU, chiller,etc

Singapore

8

Elektro Werner Heitzinger

Heat recovery air handling unit

Austria

9

Nyborg Marine Equipments AS

Marine Air Handling Units

Norway

10

Wilfred Limited

Heat recovery air handling unit

UK
 

Contact way:
Carrie Mak
GuangDong Head-Power Air Conditioning Co.,Ltd.
Add: Shiling Chenbian Section, 321 National Highway, Shishan Town,
Nanhai District, Foshan,Guangdong,China.
Mobile :86-15024293999
Fax:86-757-86688063
 
http://www.china-headpower.com

Car Rear Wing Spoiler

Car Rear Wing Spoiler,Toyota Hilux Rear Wing Spoiler,Rear Wing Spoiler,Racing Rear Wing Spoiler

Foshan Nanhai Txr AUTO Accessories Co., Ltd. , https://www.aeromaxfit.com