Wafer Butterfly Type Check Valve with Flanged JIS 10k or DIN Standard Bct-Wcv-01

Model NO.: BCT-WCV-01
Flow Direction: Unidirection
Standard: ANSI
Application: Industrial Usage, Water Industrial Usage, Household Usage, Power Plant, Sewage Treatment Plant
Body: 304, Wcb Iron, Ggg40, Ductile Iron, Cast Iron
Disc: Ductile Iron, Stainless Steel 304, 316, 1.4526
Seat: EPDM, NBR, PTFE
Shaft: Stainless Steel 410 or 416
Actuator: Automatic
Rubber: EPDM NBR or PTFE
Connection: Wafer
Valve Pressure: Pn10-16
Certification: ISO Ce
Type: Butterfly Wafer
Trademark: BCT
Transport Package: Export Standard Wooden Case
Specification: DN100-DN4000
Origin: China
HS Code: 8481300000
Wafer butterfly type check valve with flanged JIS 10K OR DIN Standard BCT-WCV-01
Size:DN40-DN1200
End flange:DIN (DN10,DN16,DN25), ANSI(class 150), JIS(5K,10K),BSEN(1092)
Face to face:ISO5752
Normal pressure:Normal pressure:
Body:cast iron, ductile iron, stainless steel, al-bronze
Disc:ductile iron/rubber lined Disc/stainless steel, al-bronze
Stem:410/420/416
Seat:EPDM/NBR/Wear-Resistant EPDM/Viton/Heat-Resistant EPDM/PTFE
Suitable temperature:-20~120ºC
Medium:water, oil, gas

Advantage:

1. OEM Factory : Professional manufacturer, clients from whole world.

2. High Quality, Competitive Price: Custom is accepted.

3. Complete Service: Long service Life, Fast delivery, Multilingual services.

4. Certificates: ISO9001, CE, , TS, WRAS.

5. Low MOQ: Ready for providing the sample and producing some small orders.

Specification:

Technical Date

Material Specification

Nominal Diameter

DN40-DN1000

Valve Body

Cast Iron or Ductile Iron

Nominal Pressure

PN10/PN16

 

Valve Disc


 

Cast Iron or Ductile Iron or Stainless Steel

Operation Temperature

-40°C~225°C

Flange Driling Standard

EN 1902-2 PN10/16

Seal Material

EPDM OR NBR

Suface Treatment

Painting

 

Valve Spring

 

Stainless Steel

Application

Portable water, water distribution service & feed lines, sewage disposol, irrigation, fire protection pipe systerm, etc.

 

1. Product catalogue:

Wafer Butterfly Type Check Valve with Flanged JIS 10k or DIN Standard Bct-Wcv-01


2.BCT Customers 

Wafer Butterfly Type Check Valve with Flanged JIS 10k or DIN Standard Bct-Wcv-01

 

3.Workshop and process


Wafer Butterfly Type Check Valve with Flanged JIS 10k or DIN Standard Bct-Wcv-01
 

4.Inspection and test

Wafer Butterfly Type Check Valve with Flanged JIS 10k or DIN Standard Bct-Wcv-01
 

5.Packing

Wafer Butterfly Type Check Valve with Flanged JIS 10k or DIN Standard Bct-Wcv-01



 
6.Installation and application
Wafer Butterfly Type Check Valve with Flanged JIS 10k or DIN Standard Bct-Wcv-01


 

 

 

OTO Pulley type wire drawing machine

The first Safety precautions for LZ600 wire drawing machine

1. 1 Professional and technical personnel are required to carry out installation and commissioning. Before use, it is necessary to carefully read this manual and the relevant electrical instructions provided.

1. 2 Each machine and electric control cabinet shall be reliably grounded with a grounding resistance not more than 4Ω.

1. 3 There should be no accumulated water on the table top, especially near the operation box, as it can easily lead to circuit failure due to water infiltration.

1.4 It is prohibited for multiple people to operate the same equipment at the same time to avoid accidents.

1. 5 The electric control cabinet should be placed in a clean and dry room, and the door should be closed when working to prevent dust intrusion from causing device performance degradation or failure. Air conditioning is used to maintain the ambient temperature of the electric control cabinet. Frequently check the operation of the cooling fan on the top of the electric control cabinet.

1. 6 Before starting the machine, check whether the safety device is normal.

1. 7 Do not operate the components in the electrical cabinet with power. After cutting off the main power supply, wait at least five minutes, and wait until the intermediate circuit capacitance is discharged before operating the frequency converter, motor, or motor cable.

1.8 Do not touch the IC circuits on the inverter control interface board and motor control board, as static electricity may damage these circuits.

1.9 Please provide the power supply and operating environment according to the technical requirements of Section 3.2. It is not allowed to arbitrarily change the parameters of the frequency converter and PLC. The user shall be responsible for any damage to electrical components caused by human factors.

The second Delivery inspection

2. 1. Check whether the equipment is damaged and complete upon delivery (according to the packing list). If there is any damage or inconsistency with the contract, please contact the dealer or manufacturer immediately.

2. 2 The manufacturer is only responsible for quality issues arising during production, and is not responsible for damage caused during unpacking, improper installation and use, or damage caused by overload operation.

2. 3 After unpacking, the accompanying documents should be properly kept, as they are necessary during equipment installation, commissioning, and use

OTO type wire drawing machine,pulley type wire drawing machinery

Jiangyin Wanyi Machinery CO.,Ltd , https://www.wydrawmachine.com