What are the characteristics of the fault arc detector?

With the widespread use of electric energy, the number of fires caused by electrical appliances is increasing year by year. According to statistics, one third of the fires are now accounted for, ranking first in all fires. How to detect and control fires in time, effective early warning and treatment when the fire does not occur or just happened, this research direction is very meaningful in practical applications.
Fault arc detector manufacturer
In the previous explanation, I believe that everyone has some understanding of the control protection switch: When the short circuit current in the circuit exceeds a certain threshold, the device will automatically perform related setting processing to protect the safe use of the circuit. So what is the fault arc detection device used for? How does it protect the circuit in its place?
The fire causes three points: temperature, combustibles, and combustion gas. In normal industrial production and life, as long as the power transmission line reaches a certain temperature, it may cause a fire, and the arc can precisely create a high temperature. The fault arc detecting device is prepared for the case where the arc generates an instantaneous high temperature. When there is insulation damage, contact failure, lightning strike, mechanical external force and other conditions in the power transmission, the probability of occurrence of fault arc is greatly increased. The fault arc detector is used to detect the occurrence of fault arc on the line, in and around the wire insulation layer. The flammable material emits an alarm signal before it is burned, effectively reducing the chance of electrical fires.
With the popularity of electrical appliances and the state's emphasis on electrical security, the relevant national standards have been continuously updated in recent years. According to Article 9.1.3 of GB50116—2013, electrical fire monitoring systems should be based on the nature of buildings and electrical fire hazards. Set and determine the form and installation location of the electrical fire monitoring detector based on the electrical wiring and the specific conditions of the electrical equipment. The fault arc detection device shall be installed in a space above 12 m, and the length of the protection line shall not be greater than 100 m. It shall be connected to the system circuit and installed in the distribution box. In addition, if there is no fire control room and the number of electrical fire monitoring detectors is less than 8, the independent electrical fire monitoring detector can be used.

Octadecyl Erucamide

Stearyl Erucamide,Octadecyl Erucamide Cas 10094-45-8,Cas 10094-45-8,Octadecyl Erucamide

Jiangxi Zhilian New Materials Co., Ltd , https://www.zhilian163.com