Airless Spray Gun Airless Spray Gun Airless Spray Gun,Airless Paint Spray Gun,Paint Spray Gun,Spray Gun Fuzhou HVBAN Mechanical Equipment Co., Ltd. , https://www.hi-sprayer.com
Â
Because of the pre-opening there is a dampened decompression of the fluid under pressure toÂ
Â
Because of the pre-opening there is a dampened decompression of the fluid under pressure toÂ
This process occurs when paint is applied to an object through the use of an air-pressurized Spray Gun. The Sprayer Gun has a nozzle, paint basin, and air compressor. When the trigger is pressed the paint mixes with the compressed air stream and is released in a fine spray.
Types of nozzles and sprays
Due to a wide range of nozzle shapes and sizes, the consistency of the paint can be varied. The shape of the workpiece and the desired paint consistency and pattern are important factors when choosing a nozzle. The three most common nozzles are the full cone, hollow cone, and flat stream.There are two types of air-gun spraying processes. In a manual operation method the air-gun sprayer is held by a skilled operator, about 6 to 10 inches (15–25 cm) from the object, and moved back and forth over the surface, each stroke overlapping the previous to ensure a continuous coat.In an automatic process the gun head is attached to a mounting block and delivers the stream of paint from that position. The object being painted is usually placed on rollers or a turntable to ensure overall equal coverage of all sides.
Sv20 Pilot Operated Check Valve
Model NO.: SV20PA1-40
Pressure: High Pressure
Valve Structure: Pilot Piston Structure
Power Supply: DC Solenoid Valve
Usage: Emptying
Standard: DIN
Application: Industrial Usage, Water Industrial Usage, Household Usage
Nodular Cast Iron: Qt500
Trademark: Power or OEM
Transport Package: Carton
Specification: ISO9001
Origin: China
HS Code: 8481201000
Model NO.: SV20PA1-40
Pressure: High Pressure
Valve Structure: Pilot Piston Structure
Power Supply: DC Solenoid Valve
Usage: Emptying
Standard: DIN
Application: Industrial Usage, Water Industrial Usage, Household Usage
Nodular Cast Iron: Qt500
Trademark: Power or OEM
Transport Package: Carton
Specification: ISO9001
Origin: China
HS Code: 8481201000
- For sub-plate mounting,
  porting pattern to DIN 24 340 Form A,
  ISO 5781 and CETOP-RP 121 H,
- For threaded connection
- With or without drain port
- With or without unloading function
- 4 cracking pressures
SV and SL valves are hydraulic pilot operated check valves in poppet type design which may beÂ
opened to permit reverse flow.
These valves are used for the isolation of operating circuits under pressure, to prevent a load from falling or  creeping movements of hydraulically locked-in actuators.
Basically these valves consist of housing (1), poppet (2),compression spring (3), control spool (4) as well as a optional pre-opening ball poppet valve (5).
Type SV (without drain port)The valve enables free flow from A to B, in theÂ
counter direction the poppet (2) is held on its seat by the system pressure, additionally to the springÂ
force. Through the pressure connection at control port X the control piston (4) is moved to the right.Â
This pushes the poppet (2) from the seat, then fluid flows from B to A.
Function and configuration
In order to ensure the proper opening of the valve via the control piston (4) a certain minimum control pressure is necessary.
Type SV...A...and SL...A... (with pre-opening) Â Â
This valve has a additional pre-opening see hereinafter left configuration. Through pressureÂ
connection at control port X the control piston (4) is pushed to the right. The ball poppet(5.1) leavesÂ
first  then the poppet (2) leaves from the seat.Â
Now the valve may also have a flow from B to A.
avoid possible pressure shocks.
Type SL... (with drain port )
The function of this valve is principally the same as the valve SV Â hereinafter right configuration.
The difference is the additional leakage port Y.Â
The annulus area of the control piston (4) is separated from port A. The pressure at port A onlyÂ
effects area A4 (9) of the control piston (4).
- For sub-plate mounting,
  porting pattern to DIN 24 340 Form A,
  ISO 5781 and CETOP-RP 121 H,
- For threaded connection
- With or without drain port
- With or without unloading function
- 4 cracking pressures
SV and SL valves are hydraulic pilot operated check valves in poppet type design which may beÂ
opened to permit reverse flow.
These valves are used for the isolation of operating circuits under pressure, to prevent a load from falling or  creeping movements of hydraulically locked-in actuators.
Basically these valves consist of housing (1), poppet (2),compression spring (3), control spool (4) as well as a optional pre-opening ball poppet valve (5).
Type SV (without drain port)The valve enables free flow from A to B, in theÂ
counter direction the poppet (2) is held on its seat by the system pressure, additionally to the springÂ
force. Through the pressure connection at control port X the control piston (4) is moved to the right.Â
This pushes the poppet (2) from the seat, then fluid flows from B to A.
Function and configuration
In order to ensure the proper opening of the valve via the control piston (4) a certain minimum control pressure is necessary.
Type SV...A...and SL...A... (with pre-opening) Â Â
This valve has a additional pre-opening see hereinafter left configuration. Through pressureÂ
connection at control port X the control piston (4) is pushed to the right. The ball poppet(5.1) leavesÂ
first  then the poppet (2) leaves from the seat.Â
Now the valve may also have a flow from B to A.
avoid possible pressure shocks.
Type SL... (with drain port )
The function of this valve is principally the same as the valve SV Â hereinafter right configuration.
The difference is the additional leakage port Y.Â
The annulus area of the control piston (4) is separated from port A. The pressure at port A onlyÂ
effects area A4 (9) of the control piston (4).