Open type incubated shaker Features: 1. Well constructed for long term operation. 2. Advance technology ensuring mechanical stability and reliability of operation. 3. Shaking mechanism is constructed with chromium alloy material and high quality cast iron. 4. Circuit breaker protect against excess current, power-off memory to return to original setting, soft start prevents splashing, auto cut-off if motor overheat. 5. Precision microprocessor control system, accuracy of speed ± 1rpm. 6. Brushless high torque motor, maintenance free. Parameters: Model HNY-810 HNY-820 HNY-850 HNY-880 Control mode P.I.D microcomputer processing chip Oscillation mode convolution Reciprocate convolution Reciprocate Display LED digital display Cyclotron frequency range 30-300rpm/min Cyclotron accuracy ±1 Shake plate shimmy range(mm) Ø26  Max configuration 100ml*22/250ml*12/500ml*8 250ml*92/500ml*66/1000ml*36(double)  Standard configuration 250ml*12 250ml*46(double) Plate size(mm) 430*325 800*600 Plate number 1 2(double) Size(mm) 456*380*195 900*640*780(double) Power(w) 80 200 Voltage AC220±10% 50-60HZ  Horizontal type incubator shaker series: This type of instrument is widely used in germ culture, ferment, hybridization, and research of biochemical reaction; enzyme and cellular tissue and all those require high temperature and oscillation frequency. Control feature: Function of parameters memory and electricity incoming recovery when data lost because of power cut or system Structure Feature:Sort: Microcomputer LCD type Performance feature: 1 P.I.D environmental scanning micro-processing controller and intelligentized audio and visual alarm,The large LCD screen clearly indicates the preset and real parameters. 2 The operating parameter locked by encryption prevents misoperation.7.Operating parameter memory function avoids monotonous operations AC inductive long-life motor design, broad speed regulation, constant torque, constant speed of rotation, no carbon brush and maintenance free. 3 Over-temperature audio and visual alarming function can automatically cut off the power when the motor overheated, temperature out of control or abnormal temperature occurs. Provided with power-off recovery function, the equipment can automatically recover to run according to the originally designed programs when the external power is recovered after a sudden cut off. 4 Wiring of the acceleration control ensures soft start, smooth acceleration and the security of samples. The luxurious streamline mould involving aesthetic designing, static plastic-spraying case and large toughened glass window. Use of microcomputer intelligent control system, powerful, strong anti-interference ability. 5 Can achieve the 1-24 time period of the day and night free combination of temperature and illumination parameters of ten sections of programming. Whole quiet design, electrostatic spray cabinet with tempered glass observation window, always observe the inside temperature and light conditions. 6 The top of the built-in light, special biological light source spectral characteristics, high strength, fever, particularly suitable for the experimental requirements Table-top type shaking incubator Control Feature: Function of parameters memory and electricity incoming recovery when data lost because of power cut or system halted. Structure Feature: Sort: Microcomputer LCD type Performance Feature: 1.P.I.D environmental scanning micro-processing controller and intelligentized audio and visual alarm,The large LCD screen clearly indicates the preset and real parameters. 2.The operating parameter locked by encryption prevents misoperation.7.Operating parameter memory function avoids monotonous operations 3.AC inductive long-life motor design, broad speed regulation, constant torque, constant speed of rotation, no carbon brush and maintenance free. 4.Over-temperature audio and visual alarming function can automatically cut off the power when the motor overheated, temperature out of control or abnormal temperature occurs. 5.Provided with power-off recovery function, the equipment can automatically recover to run according to the originally designed programs when the external power is recovered after a sudden cut off. 6.Wiring of the acceleration control ensures soft start, smooth acceleration and the security of samples. 7.The luxurious streamline mould involving aesthetic designing, static plastic-spraying case and large toughened glass window.  Parameters: Model HNY-209 HNY-100B HNY-100D HNY-200B HNY-200D Control mode P.I.D microcomputer processing chip Convection mode Forced convection Oscillation mode convolution Display LED digital display LCD display USB data download system No Yes Cyclotron frequency range 40-500rpm/min 30-600rpm/min Cyclotron frequency accuracy ±1rpm Shake plate shimmy range(mm) Ø26  Ø26  Ø0-50  Ø26  Ø0-50  Max configuration 50ml*16/100ml*10/ 250ml*8 100ml*23/250ml*12/500ml*9/1000ml*5 Standard configuration 50ml*4/100ml*3/ 250ml*3 500ml*3 250ml*3 100ml*4  50ml*4 500ml*3 250ml*4 100ml*5  50ml*5 Pallet size(mm) 220*280 450*410 410*360 450*410 410*360 Timing(h) 0-166 0-999 Temp.range(°C) 10-60 Ambient temp.+5-60 4-60 Temp. accuracy(°C) ±0.1 Temp. uniformity(°C) ≤0.5(37°C) Temp. fluctuation(°C) ≤0.2(37°C) Pallet number 1 Size(mm) 550*510*440 DC Motor Yibin Tianruida Auto Parts Co.,Ltd , https://www.trdautoparts.com
Summary:
This type of instrument is widely used in germ culture, ferment, hybridization, and research of biochemical reaction; enzyme and cellular tissue and all those require high temperature and oscillation frequency
Control feature:
Function of parameters memory and electricity incoming recovery when data lost because of power cut or system halted
Structure feature:
Sort: Microcomputer LCD type
Performance feature:
1.P.I.D environmental scanning micro-processing controller and intelligentized audio and visual alarm,The large LCD screen clearly indicates the preset and real parameters.
2.The operating parameter locked by encryption prevents misoperation.7.Operating parameter memory function avoids monotonous operations
3.AC inductive long-life motor design, broad speed regulation, constant torque, constant speed of rotation, no carbon brush and maintenance free.
4.Overtemperature audio and visual alarming function can automatically cut off the power when the motor overheated, temperature out of control or abnormal temperature occurs.
5.Provided with power-off recovery function, the equipment can automatically recover to run according to the originally designed programs when the external power is recovered after a sudden cut off.
6.Wiring of the acceleration control ensures soft start, smooth acceleration and the security of samples.
7.The luxurious streamline mould involving aesthetic designing, static plastic-spraying case and large toughened glass window.
Parameters:
Model
HNY-1102C
HNY-2102C
HNY-1102
HNY-2102
HNY-1112B
HNY-2112B
HNY-1112F
HNY-2112F
Control mode
P.I.D microcomputer processing chip
Convection mode
Forced convection
Oscillation mode
convolution
Reciprocate
Display
LCDÂ display
USB data download system
Yes
Kudan control system
Yes
Cyclotron frequency range
30-300rpm/min
30-280rpm/min
Cyclotron frequency accuracy
±1
Shake plate shimmy range(mm)
Ø26
Ø26(Ø35)
0-50
Max configuration
100ml*48/250ml*24/
500ml*24100ml*90/250ml*56/500ml*48
250ml*90/500ml*74/1000ml*36
Standard configuration
250ml*24
250ml*28
500ml*22250ml*45
500ml*36
Pallet size(mm)
500*350
745*450
970*560
Timing(h)
0-999
Temp. range(ºC)
Ambient temp.+5-60
4-60
Ambient temp.+5-60
4-60
Ambient temp.+5-60
4-60
Ambient temp.+5-60
4-60
Temp.accuracy
±0.1ºC
Temp. uniformity(ºC)
≤0.5(37ºC)
Temp. fluctuation(ºC)
≤0.2(37ºC)
Plate number
2
Size(mm)
700*560*1260
950*700*1260
1200*820*1560
Volume(L)
175
335
580
Power(w)
600
850
900
1150
1100
1400
1100
1400
Voltage
AC220±10% 50-60HZ
Ambient temp.(ºC)
5-25
Summary:
Model
HNY-111A
HNY-211A
HNY-111B
HNY-211B
HNY-111C
HNY-211C
HNY-111F
HNY-211F
Control mode
P.I.D microcomputer processing chip
Convection mode
Forced convection
Oscillation mode
convolution
Reciprocate
Display
LCDÂ display
USB data download system
Yes
Kudan control system
Yes
Lllumination
4Â Â 12000LX(max)
No
Cyclotron frequency range
30-300rpm/min
Cyclotron frequency accuracy
±1
Shake plate shimmy range(mm)
Ø26
0-50
Max configuration
100ml*66/250ml*45/
500ml*28
100ml*18/2000ml*11250ml*45/500ml*28/1000ml*18/2000ml*11/5000ml*6
250ml*46/500ml*33/1000ml*18
Standard configuration
Â
500ml*282000ml*8
500ml*33
Pallet size(mm)
920*510
800*520
Timing(h)
0-999
Temp. range(ºC)
Ambient temp.+5-60
4-60
Ambient temp.+5-60
4-60
Ambient temp.+5-60
4-60
Ambient temp.+5-60
4-60
Temp.accuracy
±0.1ºC
Temp. uniformity(ºC)
≤0.5(37ºC)
Temp. fluctuation(ºC)
≤0.2(37ºC)
Plate number
1
Size(mm)
1200*740*800
1200*740*1000
1200*740*800
Volume(L)
188
260
188
Power(w)
1100
1300
650
900
650
950
650
900
Voltage
AC220±10% 50-60HZ
Ambient temp.(ºC)
5-25
Â
Horizontal Type Shaking Incubator
Model NO.: HNY-211C
Trademark: Nanbei
Transport Package: Export Standard Packaging
Specification: CE, ISO 9001, ISO 14001 confirmed
Origin: Zhengzhou, Henan
Model NO.: HNY-211C
Trademark: Nanbei
Transport Package: Export Standard Packaging
Specification: CE, ISO 9001, ISO 14001 confirmed
Origin: Zhengzhou, Henan